Location, climate control, security, energy ... all in the green zone!



New data centre at Scandinavia's largest media hub

Requirements:
  • Continuous, homogeneous cooling air for all servers with low energy consumption
  • Side-to-side cooling required
  • Monitoring of power consumption, temperature and humidity at cabinet level
  • To be user-friendly for facility management and IT
The solution:
  • Cold aisle containment to reduce energy consumption
  • Turnkey solution including installation and power cabling
  • Automated double sliding doors to each containment area
  • Special air baffles and side panels on each cabinet for optimised side-to-side airflow
  • Combination of solid and perforated doors
  • Inline-Meters to monitor power, temperature and humidity
  • On-site installation and training given in the power management software to consolidate the monitoring of the parameters


Colocation data centre for a leading German telecommunications provider

  Requirements:
  • Physical separation of the partitions of different customers, access control
  • Cabinets with different numbers of compartments
  • Flexible cooling concept with modular upgrade options
The solution:
  • Schroff VARISTAR colocation cabinets with 2 and 4 compartments
  • Uncomplicated containment options for cabinets when cooling needs increase
  • Cabinets prepared for subsequent installation of air/water heat exchangers to support the false-floor cooling as cooling needs increase
  • Delivery, installation and commissioning of cabinet infrastructure


French provider of hosting services

  Requirements:
  • Construction of a new data centre for hosting services
  • Constantly homogeneous cold air for all servers with low energy consumption
  • Future-proof cooling, power and cable management
  • User-friendly for facility management and IT
The solution:
  • Standard Schroff containment system to reduce energy consumption
  • Rapid delivery times and minimum engineering outlay
  • Automatic standard sliding door with inside and outside switches, plus automatic closing after a defined time interval to minimise loss of cold air
  • Transparent cover panels - translucent, sealed
  • On-site installation and parametrisation


Energy-efficient data centre equipped for the future

Requirements:
  • New data centre for an international bank
  • Constantly homogeneous cold air for all servers with low energy consumption
  • Future-proof cooling, power and cable management
  • User-friendly for facility management and IT
The solution:
  • Cold aisle containment to reduce energy consumption
  • Automated, fully glazed double doors minimise leakage of cold air
  • Highly-perforated floor panels for maximum air passage
  • Transparent top cover elements allow use of room lighting into the contained aisle
  • Aisle roof panels fitted higher than the cabinets, for headroom and a sense of space
  • Cable duct integrated into aisle roof panels, accessible from cold aisle
  • Additional cable ducts along cabinet top covers


Consolidation and virtualisation in a former coal cellar

  Requirements:
  • Consolidation of servers and applications from the various departments of a university into a new data centre
  • Limited usable space, obstructed by pillars
  • Low ceiling height, no raised floor possible for air cooling
The solution:
  • Server cabinets with LHX 20 air/water heat exchangers
  • Optimal use of footprint and room height
  • Microcontroller-regulated temperature control
  • Interfaces for alarm outputs and warning signals, for external cabinet control devices and for system monitoring
  • Delivery, installation and commissioning of cabinet infrastructure


Effective server cooling

  Requirements:
  • High cooling capacity - upgrade from room air-conditioned cooling concept
  • Low noise level - the installation site is in a laboratory environment where people work
  • Limited floor space available - needed to be compact
The solution:
  • Server cabinets with LHX 20 air/water heat exchangers
  • Cooling capacity up to 20 kW
  • Noise level of only 50.7 dB(A)
  • Footprint kept small despite high cooling requirement
  • Energy-saving temperature control by microcontrollers